High Cycle Life
- The CCS Belleville Spring reduces switch element mechanical wear which in turn prolongs contact life
- CCS switches have no moving parts except during actuation and de-actuation
- CCS engineering is based on aerospace technology
- Well suited for high-impulse hydraulic applications
Over Pressure Capability
- Proof pressure is the maximum pressure that may be applied to the switch without causing permanent degradation
- CCS switches will function to specification when proof pressure is applied
- Competition definition states “switch may become inoperable”
Repeatable and Accurate
- Repeatability is the maximum set point deviation of a single pressure switch under one set of environmental and operating conditions
- CCS switch repeatable: – 1% set point
- Constant rate competitive devices: – 2% full scale
Wide Range
- CCS offers products from vacuum to positive pressure including crossover vacuum to gage pressure switches
- 28.5” Hg Vacuum to 16,000 PSIG.The CCS Belleville spring works at both the bottom and the top of adjustment range
- With competitive constant rate devices, set points are only recommended at the upper 2/3 of the adjustment range
CCS Non-haz Products | Series | Type | Setpoint Range | Operating Temp | Literature |
---|---|---|---|---|---|
Gage Pressure Switches | |||||
604G | Diaphragm | 0.3-5000 PSIG | -40 to 186 °F | Datasheet | |
604P | Piston | 10-5000 PSIG | -40 to 186 °F | Datasheet | |
605G | Diaphragm | 0.3-5000 PSIG | -40 to 186 °F | Datasheet | |
605P | Piston | 10-5000 PSIG | -40 to 186 °F | Datasheet | |
611G | Diaphragm | 0.75-180 PSIG | -40 to 186 °F | Datasheet | |
675G800 | Diaphragm | 0.7-31" H2O | -40 to 186 °F | Datasheet | |
6700 | Diaphragm | 5-150 PSIG | -30 to 160 °F | Datasheet | |
6712 | Piston | 15-3300 PSIG | -30 to 160 °F | Datasheet | |
6750G | Diaphragm | 5-150 PSIG | -30 to 160 °F | Datasheet | |
6753P | Piston | 15-3290 PSIG | -30 to 160 °F | Datasheet | |
6860G | Diaphragm | 1.5" H2O - 100 PSIG | -40 to 186 °F | Datasheet | |
6862G | Diaphragm | 1.5" H2O - 100 PSIG | -40 to 186 °F | Datasheet | |
6900G | Diaphragm | 1-3400 PSIG | -40 to 186 °F | Datasheet | |
6900P | Piston | 5-16,000 PSIG | -40 to 186 °F | Datasheet | |
Differential Pressure Switches | |||||
604D | Diaphragm | 0.3-75 PSID | -40 to 186 °F | Datasheet | |
605D | Diaphragm | 0.4-75 PSID | -40 to 186 °F | Datasheet | |
674D | Diaphragm | 2-800 PSID | -40 to 186 °F | Datasheet | |
675D800 | Diaphragm | 0.7-31" H2O | -40 to 186 °F | Datasheet | |
6900DZ | Diaphragm | 0.4-75 PSID | -40 to 186 °F | Datasheet | |
Vacuum Switches | |||||
604V | Diaphragm | 1-28.5" HG | -40 to 186 °F | Datasheet | |
605V | Diaphragm | 1-28.5" HG | -40 to 186 °F | Datasheet | |
611V | Diaphragm | 1.5-28.5" HG | -40 to 186 °F | Datasheet | |
675V800 | Diaphragm | 0.7-31" HG | -40 to 186 °F | Datasheet | |
Crossover Switches | |||||
604GV | Diaphragm | 20" HG - 12 PSIG | -40 to 186 °F | Datasheet | |
Temperature Switches | |||||
604T | Probe | -39 to 420 °F | -40 to 186 °F | Datasheet | |
604TU | Capillary | -39 to 630 °F | -40 to 186 °F | Datasheet | |
605T | Probe | -39 to 420 °F | -40 to 186 °F | Datasheet | |
605TU | Capillary | -39 to 630 °F | -40 to 186 °F | Datasheet | |
6900T | Probe | 0 to 405 °F | -40 to 186 °F | Datasheet | |
6900TU | Capillary | 0 to 650 °F | -40 to 186 °F | Datasheet |