High Cycle Life

  • The CCS Belleville Spring reduces switch element mechanical wear which in turn prolongs contact life
  • CCS switches have no moving parts except during actuation and de-actuation
  • CCS engineering is based on aerospace technology
  • Well suited for high-impulse hydraulic applications

Over Pressure Capability

  • Proof pressure is the maximum pressure that may be applied to the switch without causing permanent degradation
  • CCS switches will function to specification when proof pressure is applied
  • Competition definition states “switch may become inoperable”

Repeatable and Accurate

  • Repeatability is the maximum set point deviation of a single pressure switch under one set of environmental and operating conditions
  • CCS switch repeatable: – 1% set point
  • Constant rate competitive devices: – 2% full scale

Wide Range

  • CCS offers products from vacuum to positive pressure including crossover vacuum to gage pressure switches
  • 28.5” Hg Vacuum to 16,000 PSIG.The CCS Belleville spring works at both the bottom and the top of adjustment range
  • With competitive constant rate devices, set points are only recommended at the upper 2/3 of the adjustment range

CCS Non-haz Products Series Type Setpoint Range Operating Temp Literature
Gage Pressure Switches
604G Diaphragm 0.3-5000 PSIG -40 to 186 °F Datasheet
604P Piston 10-5000 PSIG -40 to 186 °F Datasheet
605G Diaphragm 0.3-5000 PSIG -40 to 186 °F Datasheet
605P Piston 10-5000 PSIG -40 to 186 °F Datasheet
611G Diaphragm 0.75-180 PSIG -40 to 186 °F Datasheet
675G800 Diaphragm 0.7-31" H2O -40 to 186 °F Datasheet
6700 Diaphragm 5-150 PSIG -30 to 160 °F Datasheet
6712 Piston 15-3300 PSIG -30 to 160 °F Datasheet
6750G Diaphragm 5-150 PSIG -30 to 160 °F Datasheet
6753P Piston 15-3290 PSIG -30 to 160 °F Datasheet
6860G Diaphragm 1.5" H2O - 100 PSIG -40 to 186 °F Datasheet
6862G Diaphragm 1.5" H2O - 100 PSIG -40 to 186 °F Datasheet
6900G Diaphragm 1-3400 PSIG -40 to 186 °F Datasheet
6900P Piston 5-16,000 PSIG -40 to 186 °F Datasheet
Differential Pressure Switches
604D Diaphragm 0.3-75 PSID -40 to 186 °F Datasheet
605D Diaphragm 0.4-75 PSID -40 to 186 °F Datasheet
674D Diaphragm 2-800 PSID -40 to 186 °F Datasheet
675D800 Diaphragm 0.7-31" H2O -40 to 186 °F Datasheet
6900DZ Diaphragm 0.4-75 PSID -40 to 186 °F Datasheet
Vacuum Switches
604V Diaphragm 1-28.5" HG -40 to 186 °F Datasheet
605V Diaphragm 1-28.5" HG -40 to 186 °F Datasheet
611V Diaphragm 1.5-28.5" HG -40 to 186 °F Datasheet
675V800 Diaphragm 0.7-31" HG -40 to 186 °F Datasheet
Crossover Switches
604GV Diaphragm 20" HG - 12 PSIG -40 to 186 °F Datasheet
Temperature Switches
604T Probe -39 to 420 °F -40 to 186 °F Datasheet
604TU Capillary -39 to 630 °F -40 to 186 °F Datasheet
605T Probe -39 to 420 °F -40 to 186 °F Datasheet
605TU Capillary -39 to 630 °F -40 to 186 °F Datasheet
6900T Probe 0 to 405 °F -40 to 186 °F Datasheet