The Fireye MicroM Series Flame Safeguard Control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel. The MicroM is designed to be backward compatible with existing TFM, UVM and M-Series II controls. The MicroM MEC120 and MEC230 chassis with the appropriate MEP100, MEP200 and MEP500 series programmers provide operation similar to its predecessors and is usually directly interchangeable. The MEC320 and MEC480 chassis with the appropriate MEP300, MEP400 and MEP600 series programmers provide additional enhancements such as early spark termination, pilot proving, and interrupted pilot.

[CHASSIS] [PROGRAMMER MODULES] [FLAME AMPLIFIERS] [WIRING BASES AND ACCESSORIES]

MicroM:

Part Number Description Literature
MEC120 120 VAC input with standard plug-in board Manual
MEC120R 120 VAC input with remote reset Manual
MEC120D 120 VAC input with display interface (ED510) Manual
MEC120RD 120 VAC input with display interface (ED510) and remote reset Manual
MEC120C 120 VAC input with E500 communication interface and Modbus Manual
MEC120RC 120 VAC input with display interface (ED510), E500 communication interface, remote reset, and Modbus Manual
MEC230 230 VAC input with standard plug-in board Manual
MEC230RC 230 VAC input with display interface (ED510), remote reset, and Modbus Manual
MEC320 120 VAC input with standard plug-in board Manual
MEC320R 120 VAC input with remote reset Manual
MEC320D 120 VAC input with display interface (ED510) Manual
MEC320RD 120 VAC input with display interface (ED510) and remote reset Manual
MEC320C 120 VAC input with E500 communication interface and Modbus Manual
MEC320RC 120 VAC input with display interface (ED510), E500 communication interface, remote reset, and Modbus Manual
MEC320TS 120 VAC input with display interface (ED510), E500 communication interface, Modbus, and aux relay with dry contact (MED8) Manual
MEC480 230 VAC input with standard plug-in board Manual
MEC480RC 230 VAC input with display interface (ED510), remote reset, and Modbus Manual

 

Programmer Modules:

Part Number Compatible Chassis Description Literature
MEP100 MEC120,230 Relight operation, 10 sec. PTFI Manual
MEP101 MEC120,230 Relight operation, allow flame signal until 60 seconds after interlock closed Manual
MEP102 MEC120,230 Non-recycle on flame fail, 5 second PTFI Manual
MEP103 MEC120,230 Fixed 10 second spark igniter sensing period, 10 sec. MTFI, retry once on igniter fail, fixed 30 sec. purge Manual
MEP104 MEC120,230 Non-recycle on flame fail, 10 second PTFI Manual
MEP105 MEC120,230 Non-recycle on flame fail, lockout on air-flow open with flame present, 10 second PTFI Manual
MEP106 MEC120,230 Same as MEP100, 12 second pre-purge, added reset from lockout via line voltage Manual
MEP107 MEC120,230 Same as MEP100, forced 5 minute purge delay after main flame fail Manual
MEP108 MEC120,230 Same as MEP100 with 0 second purge, 15 second PTFI, non-recycle on flame fail, NOT FM APPROVED Manual
MEP109 MEC120,230 Immediate ignition and pilot, 10 second fixed PTFI, 10 second MTFI, intermittent pilot, non-recycle on flame fail Manual
MEP100P MEC120,230 Relight operation, 10 second PTFI, fixed 15 second post purge Manual
MEP130 MEC120,230 Same as MEP100, 30 second PTFI, NOT FM APPROEVD Manual
MEP230 MEC120,230 Selectable purge timing (7, 30, 60, 90 sec), 10 second PTFI timing, recycle/non-recycle, post-purge, prove air open at start Manual
MEP230H MEC120,230 Same as MEP230 with 8 second pilot stabilization Manual
MEP235 MEC120,230 Same as MEP230 with lockout on air flow open 10 seconds after start of a cycle, selectable recycle/non-recycle lockout on air flow open after flame is proved and dedicated lockout after loss of flame Manual
MEP236 MEC120,230 Same as MEP230 with additional 6 second igniter on time with main fuel. For use with intermittent pilot only Manual
MEP237 MEC120,230 Same as MEP230 with fixed PTFI timing and check/run switch. Used with MEDC2 amplifier to provide operation with 85 Series and 95 Series scanners Manual
MEP238 MEC120,230 Same as MEP230, ignition de-energized 3 seconds after pilot flame detected. Provides 8 second pilot stabilization period Manual
MEP290 MEC120,230 Same as MEP230 except selectable post purge is 0 or 90 seconds Manual
MEP560 MEC120,230 Same as MEP230H, 10 second MTFI, run/check switch Manual
MEP561 MEC120,230 Same as MEP560 without 8 second pilot stabilization. Selectable purge time of 7, 10, 15, or 30 seconds Manual
MEP562 MEC120,230 Same as MEP560, lockout on loss of air flow, non-recycle operation only Manual
MEP564 MEC120,230 Same as MEP560, selectable purge time of 7, 30, 60, or 240 seconds Manual
MEP536 MEC120,230 Same as MEP230, 10 second MTFI, run/check switch, will not lockout on air flow open during purge Manual
MEP537 MEC120,230 Same as MEP536 except provides one recycle on main flame failure Manual
MEP300 MEC320,480 Relight operation, 10 sec. fixed PTFI, 5 sec. pilot proving period, 5 second MTFI, lockout on flame fail during PTFI, pilot proving and MTFI, recycle on air flow open, no post purge, reset on line voltage Manual
MEP304 MEC320,480 Non-recycle on flame fail, 5 sec. purge, 10 sec. fixed PTFI, 5 sec. pilot proving, 10 sec. MTFI, interrupted pilot, early spark termination Manual
MEP335 MEC320,480 Non-recycle on flame fail, 30 second purge, 35 second hot surface ignition on terminal 4, 3 second PTFI on terminal 3, 5 sec. pilot proving period, intermittent pilot, 15 sec. post purge, manual reset only Manual
MEP397 MEC320,480 Recycle on main flame fail, 15 sec. purge, 7 sec. fixed PTFI, 5 sec. pilot proving, 5 sec. MTFI, early spark termination, interrupted pilot, recycle on air flow failure, no post purge, run/check switch, reset on line voltage Manual
MEP437 MEC320,480 Recycle once on main flame fail, selectable 5 or 10 sec. PTFI, selectable interrupted or intermittent pilot, 5 sec. MTFI, selectable purge time to 240 sec., main valve proof of closure, 15 sec. post purge, reset on line voltage Manual
MEP696 MEC320,480 Provides 30 sec. pre-purge, lockout on airflow after 10 sec., 10 sec. PTFI, 5 sec. pilot proving, early spark termination, 5 sec. MTFI, interrupted pilot, selectable recycle/non-recycle on flame fail, 60 sec. post purge, selectable baud rate for communications, output for external controller operation Manual
MEP697 MEC320,480 Provides dip-switch selectable pre-purge, selectable air flow proving at startup, selectable post purge, selectable 5/10 sec. PTFI, 5 sec. pilot proving early spark termination, 5 sec. MTFI, interrupted pilot, selectable recycle/non recycle on flame fail, output for external controller operation Manual

 

Amplifier Modules:

Part Number Description Literature
MEUV1 UV amplifier, 0.8 second FFRT, for UV1A, UV2, UV8A, UV90, and 45UV3-1050 scanners Manual
MEUV4 UV amplifier, 3 second FFRT, for UV1A, UV2, UV8A, UV90, and 45UV3-1050 scanners Manual
MEUVS1 UV Self-check amplifier, 0.8 second FFRT, for 45UV5-1009 scanner Manual
MEUVS4 UV Self-check amplifier, 3 second FFRT, for 45UV5-1009 scanner Manual
MERT1 Flame rod amplifier, 0.8 second FFRT Manual
MERT4 Flame rod amplifier, 3 second FFRT Manual
MEIR1 Infrared amplifier, 0.8 second FFRT, for 48PT2 scanner Manual
MEIR4 Infrared amplifier, 3 second FFRT, for 48PT2 scanner Manual
MECD1 Cadmium sulfide amplifier, 0.8 second FFRT, for CS1A5 scanner Manual
MECD4 Cadmium sulfide amplifier, 3 second FFRT, for CS1A5 scanner Manual
MEDC2 Contact input amplifier for use with MEP237 to provide operation with 85 Series and 95 Series scanners Manual

 

Wiring Bases and Accessories:

Part Number Description Literature
61-3060 Closed wiring base, surface mounting Manual
61-5042 Open wiring base, cabinet mounting Manual
MED1 (Option Board) Standard local reset switch Manual
MED2 (Option Board) Local reset, display output Manual
MED3 (Option Board) Local reset, remote reset Manual
MED4 (Option Board) Local reset, display output, remote reset Manual
MED5 (Option Board) Local reset, display output, RS485 communications Manual
MED6 (Option Board) Local reset, display output, remote reset, RS485 communications Manual
MED7 (Option Board) Local reset, RS485 communications Manual
MED8 (Option Board) Local reset, display output, RS485 communications, aux. relay (normally closed dry contacts) Manual
MED9 (Option Board) Local reset, display output, RS485 communications, aux. relay (normally open dry contacts) Manual
ED510 Back-lit LCD display with keypad Manual
ED580-2 Remote display cable with RJ45 connection, 2 feet
ED580-4 Remote display cable with RJ45 connection, 4 feet
ED580-8 Remote display cable with RJ45 connection, 8 feet
EC485 RS232 to RS485 converter with power supply and RJ12 jack Manual
UC485 USB to RS485 converter with USB cable Manual
SMDK-1004 Serviceman's display kit for quick MicroM diagnosis. Includes ED510 with back plate, MED daughter board and ED580-4 Manual
129-145-1 ED510 remote display mounting kit with 4 ft. cable
129-145-2 ED510 remote display mounting kit with 8 ft. cable
129-145-3 ED510 remote display mounting kit with 2 ft. cable